Caterpillar — MAINTENANCE INTERVAL SCHEDULE (STANDBY GENERATOR SET ENGINES)

112 Maintenance Section Engine Air Cleaner Element (Dual Element) - Clean/Replace Note: Refer to “Inspecting the Primary Air Cleaner Elements”. Primary air cleaner elements elements to air dry before inspected and installed. Washing the Primary Air Cleaner Elements with Nonsudsing Detergent may be allowed to air dry. Allow two days for the primary air cleaner the elements are Inspecting the Primary Air Cleaner Elements Do not wash air cleaner elements in any flammable solution such as diesel fuel or gasoline. Doing so can cause fire or an engine runaway and can result in personal injury.

Washing with nonsudsing detergent is effective for cleaning primary air cleaner elements that have deposits of carbon or oil. Use a cleaning agent that is specifically manufactured for cleaning primary air cleaner elements. Cleaning with pressurized water, pressurized air, or a vacuum is recommended to washing with nonsudsing detergent. 1. Place the primary air cleaner element prior into a wash tank so that the gasket is up. The wash tank should be equipped with a rack so that the primary air cleaner element does not sit on the bottom of the wash tank. Note: Caterpillar does not recommend a process for washing the primary air cleaner element which includes agitation.

Agitation may particles to be distributed. cause carbon 2. Fill the wash tank with the cleaning agent and warm water to a maximum temperature of 60°C (140°F). Follow the manufacturers recommendations for the cleaning agent. Allow the primary air cleaner element to soak for six hours. 3. Drain the wash tank. Do not use the cleaning agent more than one time. Remove the primary air cleaner element from the wash tank. Rinse the primary air cleaner element with the method for using pressurized water. Note: Refer to “Drying the Primary Air Cleaner Elements”. Refer to “Inspecting the Primary Air Cleaner Elements”.

Drying the Primary Air Cleaner Elements The oven method may be used in order to dry primary air cleaner elements. If an oven is used, do not expose the primary air cleaner elements to temperatures that exceed 82°C (160°F). Note: Do not use compressed primary air cleaner elements. air in order to dry the lilustration 69 g00281693 Inspect the clean, dry primary air cleaner element. Use a 60 watt blue light in a dark room or in a similar facility. Place the blue light in the primary air cleaner element. Rotate the primary air cleaner element. Inspect the primary air cleaner element for tears and/or holes.

Inspect the primary air cleaner element for light that may show through the filter material. If it is necessary in order to confirm the result, compare the primary air cleaner element to a new primary air cleaner element that has the same part number. Do not use a primary air cleaner element that has any tears and/or holes in the filter material. Do not use an primary air cleaner element with damaged pleats, gaskets or seals. Discard damaged primary air cleaner elements. Storing Primary Air Cleaner Elements If a primary air cleaner element that passes inspection will not be used, the primary air cleaner element can be stored for future use.