Caterpillar — MAINTENANCE INTERVAL SCHEDULE (STANDBY GENERATOR SET ENGINES)

138 Maintenance Section Starting Motor - Inspect 101113939 Air Starting Motor Starting Motor - Inspect SMCS Code: 1451-040; 1453-040 If the starting motor fails, the engine may not start in an emergency situation. A scheduled inspection of the starting motor is recommended. The starting motor pinion and the flywheel ring gear must be tn good condition in order for the engine Personal injury or death can result from improperly checking for a leak. Always use a board or cardboard when checking for a leak. Escaping air or fluid under pressure, even a pin-hole size leak, can penetrate body tis- sue causing serious injury, and possible death. to start properly.

The engine will not start if the starting motor pinion does not engage the flywheel ring gear. The teeth of the starting motor pinion and the flywheel ring gear can be damaged because If fluid is injected into your skin, it must be treated immediately by a doctor familiar with this type of injury. of irregular engagement. Inspect the starting motor for proper operation. Listen for grinding when the engine is started. Inspect the teeth of the starting motor pinion and the flywheel ring gear. Look for patterns of wear on the teeth. Look for teeth that are broken or chipped. If damaged teeth are found, the starting motor pinion and the flywheel ring gear must be replaced.

Electric Starting Motor Note: Problems with the electric starting motor can be caused by the following conditions: malfunction of the solenoid and malfunction of the electric starting system. Inspect all of the components in the air circuit for the starting motor. Inspect all of the air lines and connections for leaks. If the teeth of the starting motor pinion and/or the flywheel ring gear are damaged, the air circuit for the starting motor must be examined determine the cause of the problem.

Removal and in order to Installation of the Starting Motor Refer to the Service Manual, “Disassembly and Assembly” module for information on removing the starting motor and installing the starting motor. Inspect the electrical system conditions: for the following Consult your Caterpillar dealer for assistance. e Loose connections 100571847 e Corrosion Turbocharger - Inspect e Wires that are worn or frayed SMCS Code: e Cleanliness Periodic inspection and cleaning is recommended for the turbocharger compressor housing (inlet Make repairs, if necessary. 1052-040 side), Fouling of the compressor can contribute to toss of engine power, increased black smoke and overall loss of engine efficiency.

If the turbocharger fails during engine operation, damage to the turbocharger compressor wheel and/or to the engine may occur. Damage to the turbocharger compressor wheel could allow parts from the compressor wheel to enter an engine cylinder. This can cause additional damage to the pistons, the valves, and the cylinder head.