Caterpillar — ENGINE FEATURES AND CONTROLS

32 Operation Section Engine Features and Controls e The engine is at low idle rpm for ten seconds. If the engine speed is then reduced by more than 50 rpm, the Cold Mode Cylinder Cutout is deactivated for 30 seconas. e If the fuel rack is greater than 13 mm (.5 inch), the Cold Mode Cylinder Cutout is deactivated for one second. -60 -50 -40 -30 -20 -10 Droop 20 30 This feature enables an engine to share a load with other engines. If an engine is operating at high idle rpm and a load is applied, the engine 0 rpm is reduced. The engine rpm is reduced as the load increases. This reduction in rpm is the droop. The droop can be programmed from zero to ten percent.

If the percent of droop is equal for two identical engines in parallel operation, the engines share the load equally. 0 @ 10 20 30 40 50 60 70 80 90 100110120150 140 g00576415 Illustration 29 Jacket water temperature and duration of ether injection (Y) Temperature in °C (X) Time in seconds A switch is installed on the control panel or the Ether Control instrument panel. The switch enables the operator to inject ether manually under the following conditions: Note: This is an optional feature. e The switch for ether injection is in the manual The ECM automatically injects ether into the air inlet position. manifold when the following conditions are met:

e The engine e The engine e The jacket water temperature is less than 21 °C (70 °F). rpm is between 50 and 400 rpm. e The jacket water temperature is below 21 °C (70 °F). The duration of ether injection varies linearly with the jacket water temperature. The duration of ether injection varies within the following range: e 15 seconds at the maximum temperature of 21 °C (70 °F) e 130 seconds at the minimum —40 °C (-40 °F) rpm is more than 50 rpm. Fuel Correction Factor When the engine is shipped from the factory, an estimate of the engine’s fuel consumption is programmed into the ECM. The estimate is based upon the engine’s performance specifications.

The actual fuel consumption can be determined with a meter that measures the flow of the fuel. Customers temperature of The longest duration of ether injection is 130 seconds even if the jacket water temperature is less than —40 °C (-40 °F). See Illustration 29. are likely to find a slight difference between the estimate of fuel consumption that was programmed and the actual fuel consumption. The customer can use an ET service tool to program the ECM for the actual fuel consumption. A factory level security password is required in order to change this parameter. To program the ECM for the actual fuel consumption, change the Fuel Correction Factor that is already programmed into the ECM.

The Fuel Correction Factor can be programmed in increments of 0.5 percent between + 25 percent.