34 Operation Section Engine Features and Controls The derating is cumulative. For example, a derating of five percent followed by a derating of two percent results in a total derating of seven percent. The strategy is based on a map of the engine oil pressure versus the engine rom. For engines that are rated up to 1300 rpm, see Illustration 30. For lf the conditions that cause the derating are not corrected, the derating will continue. engines that are rated at 1301 rpm and above, see Illustration 31. The default settings that are programmed Default Settings for the Caterpillar Monitoring System Derate — This is a reduction of engine horsepower in response to an abnormal operating condition.
Setpoint — This is a specific value which can activate the following responses: warning, deration, at the factory are listed in Table 6. Table 6 Engine Oil Pressure Parameter Default Settings Upper oil pressure limit 175 kPa (25 psi) Lower oil pressure limit 41 kPa (5.9 psi) High engine speed limit 1250 Low engine speed limit 452 Hysteresis — This is the change in the signal from Hysteresis 40 kPa (5.8 psi) a sensor that is tolerated by the ECM. This ts the difference between the setpoint that activates a response and the value that deactivates the Activation delay 10 seconds Security level Required password response.
For example, a warning for low voltage can activate if a value below 20 volts is detected by the ECM. The voltage must rise to 22 volts in order Warning setpoint Map Warning delay 4 seconds to clear the warning. The hysteresis is the 2 volts Shutdown setpoint Map and shutdown. The setpoint can be a pressure, speed, a temperature, or a voltage. a that are above the 20 volts. Shutdown Voltage The ECM automatically warns the operator of low system voltage. The default settings that are programmed at the factory are listed in Table 5.
Table 5 Voltage Monitoring Parameter Default Setting Warning setpoint 20 volts Warning delay 10 seconds Hysteresis 2 volts Security level No required password If the voltage is below 20 volts for 10 seconds, a warning will occur. To deactivate the warning, the voltage must rise above 22 volts. The setpoint can be programmed between 20 and 22 volts. to a value Engine Oil Pressure The ECM automatically performs the following functions for low engine oil pressure: e Warning e Shutdown delay 9 seconds