60 Operation Section Engine Starting Manual Starting The ECM will allow the engine to be operated at rated rpm when the oil pressure sensors indicate that the oil pressure is sufficient. NOTICE For initial start-up of a new or rebuilt engine, and for start-up of an engine that has been serviced, make Overcrank provision to shut the engine off should an overspeed occur. This may be accomplished by shutting off the The air and/or fuel supply to the engine. engagement of the starting motor. This also includes Do not start the engine or move any of the controls if there is a “DO NOT OPERATE” warning tag or a similar warning tag attached to the start switch or to the controls.
Ensure that no one will be endangered before the engine is started and when the engine is started. 1. Perform ali of the procedures that are described in this Operation and Maintenance Manual, “Before Starting Engine” topic (Operation Section). 2. Ensure that the main circuit for the generator is open. NOTICE Do not engage the starting motor when flywheel is turning. Do not start the engine under load. If the engine fails to start within 30 seconds, release the starter switch or button and wait two minutes to allow the starting motor to cool before attempting to start the engine again. > O85 ®) wr COOLDOWN STOP AUTO S avian.
O START g00319402 Illustration 51 Engine control switch in the “MAN. START” position Note: If the optional prelube is used, the prelube pump will operate before cranking begins. 3. To start the engine, turn the engine control switch to the “MAN. START” position. crank cycle is the amount of time for the amount of time for cooling of the starting motor between crank cycles. The crank cycle and the number of crank cycles are programmable. If the engine does not start within the number of crank cycles that are programmed, the fuel system is disabled. The “OVERCRANK” indicator will illuminate in order to warn the operator of an overcrank.
If an overcrank occurs, the ECM must be reset before starting can be attempted. To reset the ECM, turn the engine control switch to the “OFF/RESET” position.