63 Operation Section Engine Stopping Engine Stopping To reset the air shutoff, turn the reset knob to the “OPEN?” position. Ensure that both of the air shutoffs are reset. Emergency Stopping SMCS Code: 1000: 101106683 Manual Stop Procedure 7418 NOTICE Emergency shutoff controls are for EMERGENCY use ONLY. DO NOT use emergency shutoff devices or controls for normal stopping procedure. SMCS Code: 1000; 7418 NOTICE Stopping the engine immediately after it has been working under load can result in overheating and accelerated wear of engine components. Ensure that any components for the external system that support the engine operation are secured after the engine is stopped.
Excessive temperatures in the turbocharger centerhousing will cause oil coking problems. Emergency Stop Button Allow the engine to gradually cool before stopping the engine There may be several methods for shutting off the engine. Make sure that the shutoff procedures are EMERGENCY understood. Use the following general guidelines for stopping the engine. 1. Open the main circuit breaker in order to disengage the driven equipment. 2. Operate the engine for a cooldown period before stopping the engine. a. g00104303 Illustration 52 If the cooldown feature is utilized, turn the engine control switch to the “COOLDOWN/STOP” position.
Typical emergency stop button The engine will operate for a programmed The emergency stop button is in the OUT position period of time. After the cooldown, the timer for normal engine operation. For an emergency stop, push the emergency stop button. This shuts off the fuel to the engine. This also activates the air shutoff (if equipped). will activate the fuel shutoff. The engine control module will remain powered until NOTICE Do not start the engine until the problem necessitating the emergency stop has been located and corrected.
The engine control switch, the emergency stop button, and the air shutoff must be reset before the engine can be restarted, Reset the engine control switch before resetting the emergency stop button. To reset the engine control switch, turn the switch to the “OFF/RESET” position. To reset the emergency stop button, turn the button clockwise. The spring-loaded button will return to the OUT position. The button may also be pulled to the OUT position. the engine control switch is turned to the “OFF/RESET” position. b. If the cooldown feature is not utilized, operate the engine at high idle for approximately five minutes. Then stop the engine.