84 Maintenance Section Cooling System Specifications Note: The cooling system cleaner must be thoroughly flushed from the cooling system. Cooling Commercial system cleaner that is left in the system will contaminate the coolant. The cleaner may also \f Caterpillar ELC is not used, then select a commercial ELC that meets the Caterpillar specification of EC-1 and either the “ASTM D5345” corrode the cooling system. ELC specification or the “ASTM D4985” specification. Do 7. Repeat Steps 5 and 6 until the cooling system is not use an extended completely clean. the EC-1 specification. Follow the maintenance life coolant that does not meet guide for the coolant from the supplier of the 8.
Fill the cooling system with Caterpillar Premixed ELC. 9. Attach Special Publication, PEEP5027, commercial ELC. Follow the Caterpillar guidelines for the quality of water and the specified change interval. coolant “Label” to the filler of the cooling system in order to indicate the use of Caterpillar ELC. Note: Clean water is the only flushing agent that is required when the ELC is drained from the cooling 101111753 Diesel Engine Antifreeze/ Coolant (DEAC) system. SMCS Code: 1350; 1352; 1395 Contamination of the ELC Cooling System Caterpillar cooling NOTICE Mixing ELC with other products reduces the effectiveness of the ELC and shortens the ELC service life.
Use only Caterpillar products or commercial products that have passed the Caterpillar EC-1 specification for premixed or concentrate coolants. Use only Caterpillar ELC Extender with Caterpillar ELC. Failure to follow these recommendations can result in shortened cooling system component life. recommends using Caterpillar Diesel Engine Antifreeze/Coolant (DEAC) for systems that require a heavy-duty coolant/antifreeze. Caterpillar DEAC is an alkaline single-phase ethylene glycol type antifreeze that contains corrosion inhibitors and antifoam agents. Caterpillar DEAC is formulated with the correct amount of Caterpillar Supplemental Coolant Additive (SCA).
Do no use SCA at the initial fill when DEAC is used. Containers of several sizes are available. Consult your Caterpillar dealer for the part numbers. ELC cooling systems can withstand contamination to a maximum of ten percent of conventional heavy-duty coolant/antifreeze or SCA. If the contamination exceeds ten percent of the total system capacity, perform ONE of the following procedures: e Drain the cooling system into a suitable container. Dispose of the coolant according to local If concentrated recommends DEAC is used, Caterpillar mixing the concentrate with distilled water or with deionized water.
If distilled water is not available or deionized water is not available, use water which has the required properties. For the water properties, see this publication, “General Coolant Information” topic (Maintenance Section). regulations. Flush the system with clean water. Fill the system with the Caterpillar ELC. e Drain a portion of the cooling system into a suitable container according to local regulations. Then, fill the cooling system with premixed ELC. This should lower the contamination to less than 10 percent. i074 164588 Commercial Coolant/Antifreeze and SCA SMCS Code: 1350; 1352; 1395 If Caterpillar ® Maintain the system as a conventional Diesel Engine Antifreeze/Coolant (DEAC).
Treat the system with an SCA. Change the coolant at the interval that is recommended for the conventional Diesel Engine Antifreeze/Coolant (DEAC). Heavy-Duty DEAC is not used, select a coolant/antifreeze with low silicate content for heavy-duty applications that meets “ASTM D5345” or “ASTM D4985” specifications. Note: When you are not using Caterpillar DEAC the cooling system must be drained one time during every year. The cooling system must be flushed at this time as well.