Caterpillar — COOLING SYSTEM SPECIFICATIONS

87 Maintenance Section Cooling System Specifications Table 42 NOTICE Never use water alone without Supplemental Coolant Additives (SCA) or without inhibited coolant. Water alone is corrosive at engine operating temperatures. Water alone does not provide adequate protection against boiling or freezing. Example Of The Equation For Adding The SCA To Water At The Initial Fill Total Volume of the Cooling System (V) 946 | Factor for Amount of SCA Multiplication | that is Required (X) L x 0.07 66 (250 US gal) | L (18 US gal) Do not use water alone as an engine coolant. Supplemental Coolant Additive (SCA) helps to prevent the following conditions from occurring:

Adding the SCA to Water for @ Corrosion Maintenance e Formation of mineral deposits Test the mixture of SCA and water periodically for the concentration of SCA. For the interval, see e Cavitation of the cylinder liner the specific engine’s Operation and Maintenance Manual, “Maintenance Interval Schedule” e Foaming of the coolant (Maintenance Section). lf Caterpillar SCA is not used, select a commercial Test the concentration of SCA with the 8T-5296 SCA. The commercial SCA must provide a minimum of 2400 mg/L or 2400 ppm (140 grains/US gal) of nitrates in the final coolant mixture. The quality of the water is a very important factor in this type of cooling system.

Distilled water or deionized water is recommended for use in cooling systems. If distilled water or deionized water is not available, water that has the required properties may be used. For the water properties, see this Operation and Maintenance Manual, “General Coolant Information” topic (Maintenance Section). A cooling system that uses a mixture of only SCA and water requires more SCA than a cooling system Coolant Conditioner Test Kit or with S-O-S coolant analysis. For more information on coolant analysis, see this Operation and Maintenance Manual, “S-O:S Coolant Analysis” topic (Maintenance Section). Instructions are provided with the 8T-5296 Coolant Conditioner Test Kit.

Make the following modifications to Steps 3 and 5 of the instructions. These modifications are needed for mixtures of SCA and water: STEP 3 — Add tap water to the vial up to the “20 ml” mark. STEP 5 — When the defined procedure is used, and water requires six to eight percent of SCA. a concentration of six to eight percent will yield between 20 drops and 27 drops. If the number of Adding the SCA to Water at the Initial Fill is low. If the number of drops is above 27 drops, the concentration of SCA is high. Make the appropriate adjustments to the concentration of SCA. The capacity of the cooling system determines the amount of SCA that is required.

Use the equation Additions of SCA are based on the results of the test or based on the results of the coolant analysis. that is in Table 41 to determine the amount of Caterpillar SCA that is required at the initial fill. This amount of SCA that is required. that uses a mixture of glycol and water. The SCA equation is for a mixture of only SCA and water. drops is below 20 drops, the concentration of SCA The capacity of the cooling system determines the Use the equation that is in Table 43 to determine the amount of Caterpillar SCA that is required. Table 41 Equation For Adding The SCA To Water At The Initial Fill V x 0.07 = X V is the total volume of the cooling system.

X is the amount of SCA that is required. Table 42 is an example for using the equation that is in Table 41. Table 43 Equation For Adding the SCA To Water For Maintenance V x 0.023 = X V is the total volume of the cooling system. X is the amount of SCA that is required.