98 Maintenance Section Air Starting Motor Lubricator Oil Level - Check 4. Dry the bowl. Inspect the bowl for cracks. If the bow! is cracked, replace the damaged bow! with a new bowl. 5. Install the bowl. Close drain (3). Install plug (4). Adjust the Lubricator Note: Adjust the lubricator with a constant rate of air 6. Remove plug (1). Fill bow! (2) with oil. Use nondetergent “10W” oil for temperatures that are greater than 0°C (32°F). Use air tool oil for temperatures that are below O°C (32°F). oil filler plug (1). 4. Install 7. If necessary, adjust the lubricator in order to release two drops of oil per 30 seconds.
For instructions, see this Operation and Maintenance Manual, “Air Starting Motor Lubricator Oil Level Check” topic (Maintenance Section). flow. After the adjustment, the lubricator will release oil in proportion to variations of the air flow. 1. Ensure that the fuel supply to the engine is OFF. NOTICE Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking the engine again. 2. Operate the air starting motor. Observe the drops of oil that are released in dome (1). 100691572 Air Starting Motor Lubricator Oil Level - Check Note: Some lubricators have an adjustment screw rather than a knob. 3.
If necessary, adjust the lubricator in order to release two drops of oil per 30 seconds. To increase the rate, turn knob (2) counterclockwise. To decrease the rate, turn the knob clockwise. SMCS Code: 1451-535 NOTICE Never allow the lubricator bowl to become empty. The air starting motor will be damaged by a lack of lubrication. Ensure that sufficient oil is in the lubricator bowl. 100351324 Air Tank Moisture and Sediment - Drain SMCS Code: 1466-543-M&S Moisture and sediment in the air starting system can cause the following conditions: e Freezing e Corrosion of internal parts e Malfunction of the air starting system g00349048 lilustration 59 (1) Dome (2) Knob When (4) Plug 1.
Observe the oil level in sight gauge (3). If the oil level is fess than bowl. opening the drain valve, wear protective gloves, a protective face shield, protective cloth- (3) Sight gauge ing, and protective shoes. Pressurized air could cause debris to be blown and result in personal injury. 1/2, add oil to the lubricator 2. Ensure that the air supply to the lubricator is OFF. 3. Remove plug (4). Pour oil into the lubricator bowl. Use “10W” oil for temperatures that are greater than 0°C (32°F). Use air tool oil for temperatures that are below 0°C (32°F). 1. Open the drain valve that is on the bottom of the air tank. Allow the moisture and sediment to drain. 2. Close the drain valve.