Komatsu D155AX-6 — E-24 BACKUP ALARM DOES NOT SOUND OR DOES NOT STOP

SEN00807-01 40 Troubleshooting E-24 Backup alarm does not sound or does not stop 1 50 D155AX-6 Trouble • Backup alarm does not sound or does not stop. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective backup alarm relay (Internal disconnection or short circuit) a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Replace backup alarm relay (Right No.) with another relay. If backup alarm operates nor- mally at this time, backup alarm relay is defective.

BKA 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between BKA (female) (3) – branch point (F) Resis- tance Max. 1 z Wiring harness between BKA (female) (5) – BKAL (female) (1) Resis- tance Max. 1 z Wiring harness between BKAL (female) (2) – chassis ground (GND03) Resis- tance Max. 1 z 3 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between BKA (female) (5) – BKAL (female) (1) or circuit branch end and chassis ground Resis- tance Min. 1 Mz 4 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between BKA (female) (5) – BKAL (female) (1) or circuit branch end and chassis ground Voltage Max. 1 V 5 Defective backup alarm (Internal trouble) If causes 1 – 4 are not detected, backup alarm may be defective.