Komatsu D155AX-6 — E-25 HEADLAMP, REAR LAMP, AND RIPPER POINT LAMP DO NOT LIGHT UP

40 Troubleshooting SEN00807-01 D155AX-6 53 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 8 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between terminal 270 – FLSW (female) (5) or circuit branch end and chassis ground Resis- tance Min. 1 Mz Wiring harness between FLSW (female) (4), (3) – LMD1 (female) (2) or CM01 (female) (13) and chassis ground Resis- tance Min.

1 Mz Wiring harness between LMD1 (female) (1), LMD2 (female) (1) – LMFL (female) (1), LMFR (female) (1) and chassis ground Resis- tance Min. 1 Mz Wiring harness between CB4 (2) – LMFL (female) (3), LMFR (female) (3) and chassis ground Resis- tance Min. 1 Mz Wiring harness between LMFL (female) (5) – LHDL (female) (1) and chassis ground Resis- tance Min. 1 Mz Wiring harness between LMFR (female) (5) – LHDR (female) (1) and chassis ground Resis- tance Min. 1 Mz