SEN00807-01 40 Troubleshooting 62 D155AX-6 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 7 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between fuse (6) – CN13 (female) (3), (5), CN17 (female) (4), or cir- cuit branch end and chassis ground Resis- tance Min. 1 Mz Wiring harness between fuse (6) – CN30 (female) (3) or circuit branch end and chas- sis ground Resis- tance Min. 1 Mz Wiring harness between CN13 (female) (2) – CN31 (female) (3) and chassis ground Resis- tance Min.
1 Mz Wiring harness between CN31 (female) (4) – CN30 (female) (4) and chassis ground Resis- tance Min. 1 Mz Wiring harness between CN30 (female) (5) – CN17 (female) (3) and chassis ground Resis- tance Min. 1 Mz