Komatsu D155AX-6 — E-26 WINDSHIELD WIPER AND WINDOW WASHER DO NOT OPERATE

40 Troubleshooting SEN00807-01 D155AX-6 65 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 7 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between fuse (6) – CN15 (female) (3), (5) or circuit branch end and chassis ground Resis- tance Min. 1 Mz Wiring harness between fuse (6) – CN26 (female) (3), CN24 (female) (4) or circuit branch end and chassis ground Resis- tance Min. 1 Mz Wiring harness between CN15 (female) (2) – CN27 (female) (3) and chassis ground Resis- tance Min.

1 Mz Wiring harness between CN27 (female) (4) – CN26 (female) (4) and chassis ground Resis- tance Min. 1 Mz Wiring harness between CN26 (female) (5) – CN24 (female) (3) and chassis ground Resis- tance Min. 1 Mz