Komatsu D155AX-6 — E-27 KOMTRAX SYSTEM DOES NOT OPERATE NORMALLY

SEN00807-01 40 Troubleshooting E-27 KOMTRAX system does not operate normally 1 a Select "Setting condition of terminal" from "12 Display of KOMTRAX setting" in the service menu of the machine monitor. a Select "Condition of positioning and communication" from "12 Display of KOMTRAX setting" in the service menu of the machine monitor. 72 D155AX-6 Trouble • KOMTRAX system does not operate normally. • Related information • • If KOMTRAX system administrator makes request for checking system on machine side for trouble, carry out following troubleshooting. Even if KOMTRAX system has trouble, it does not particularly appear on machine.

Carry out all troubleshooting on service menu screen of machine monitor. 1 2 Possible causes and standard value in normal state 3 4 Cause Standard value in normal state/Remarks on troubleshooting Defective transmission 1 a Turn starting switch ON and check "Setting condition of termi- nal" screen. Check item Normal display Communication start check Completion Normal display Completion Defective GPS a Turn starting switch ON and check "Condition of positioning and communication" screen. Check item Normal display N ###,##,##(Latitude) Positioning E ###,##,##(Longitude) In positioning If latitude and longitude are not displayed in 5 minutes on open ground, notify KOMTRAX service hot line.

Defective communication environment a Turn starting switch ON and check "Condition of positioning and communication" screen. Check item Normal display Communication Zone level 1 – Zone level 3 If zone level 1 – 3 is not displayed within communication zone of ORBCOMM, notify KOMTRAX service hot line. Defective transmission 2 a Turn starting switch ON and check "Condition of positioning and communication" screen. Check item Normal display Number of items not transmitted 0 – 9 (Normally 0) Normal display 0 – 9 (Normally 0)