40 Troubleshooting SEN00808-00 H-9 Power train oil is overheated 1 D155AX-6 11 Trouble • Power train oil is overheated. Related information • Before carrying out troubleshooting, check that power train oil level is normal. • Before carrying out troubleshooting, check that power train oil temperature gauge indicates actual oil temperature (If it does not, carry out troubleshooting for "E-9 Power train oil temperature gauge (Multi-gauge) does not indicate normally". • Before carrying out troubleshooting, check that transmission main relief pressure is normal (See H-1).
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective engine Engine cooling system may be defective or engine output may be increased. Carry out troubleshooting for engine unit (S mode). 2 Defective power train pump or air in suction circuit Power train pump may be defective or air is in suction circuit. Check them directly. 3 Trouble in torque converter a Prepare with starting switch ON, then run engine at high idle and carry out troubleshooting. PCCS lever Torque converter inlet pressure Torque converter outlet pressure Neutral Max. 1.0 MPa {Max.
10.0 kg/cm2} 0.29 – 0.69 MPa {3.0 – 7.0 kg/cm2} 4 Malfunction of transmission clutch (Slip) Transmission clutch may be malfunctioning (slipping). Check it directly. 5 Malfunction of brake (Drag- ging) a Start engine and check. 1. Float machine above ground with blade and ripper. 2. Run engine at low idle and set transmission gear in F3 or R3. 3. If track shoe does not turn, brake is dragging. (Carry out troubleshooting for "H-8 Brake does not work".) 6 Malfunction of brake (Slip) a Start engine and check. Stall machine at F3. If machine does not stop perfectly, brake is slipping.