Komatsu D155AX-6 — H-12 NO WORK EQUIPMENT MOVES

SEN00808-00 40 Troubleshooting H-12 No work equipment moves 1 14 D155AX-6 Trouble • No work equipment moves. Related information • Before carrying out troubleshooting, check that oil level in hydraulic tank is normal. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective PTO (work equip- ment and HSS pump drive section) Work equipment and HSS pump drive section of PTO may be defective. Check them directly. 2 Defective work equipment or HSS pump Work equipment or HSS pump may be defective. Check them directly.

3 Malfunction of unload valve a Prepare with starting switch ON, then run engine at high idle and carry out troubleshooting. PCCS lever Blade control lever Ripper control lever Unload pressure Neutral 2.45 (+1.37/0) MPa {25 (+14/0) kg/cm2} 4 Improper set pressure or malfunction of main relief valve a Prepare with starting switch ON, then run engine at high idle and carry out troubleshooting. Blade control lever Main relief pressure Raise relief 27.5 ± 1.5 MPa {280 ± 15 kg/cm2} 5 Improper set pressure or malfunction of self-acting pressure reducing valve a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting.

PCCS lever Blade control lever Ripper control lever Control circuit basic pressure Neutral 3.78 – 4.46 MPa {38.5 – 45.5 kg/cm2} 6 Malfunction of work equip- ment lock solenoid valve a Prepare with engine stopped, then run engine at high idle and carry out troubleshooting. Work equipment lock lever Solenoid valve output pressure Lock 0 MPa {0 kg/cm2} Free 3.78 – 4.46 MPa {38.5 – 45.5 kg/cm2}