10 Structure, function and maintenance standard SEN00604-00 ECMV for stator clutch Outline Operation When traveling in direct range q This valve acts to set the lockup clutch oil pres- sure to the set pressure, and also to switch the lockup clutch. It forms a modulation wave pattern, so the sta- tor clutch is engaged smoothly to reduce the shock when shifting gear. In addition, it pre- vents generation of peak torque in the power train. As a result, it provides a comfortable ride for the operator and greatly increases the durability of the power train. Direct travel o torque converter travel q When traveling in direct (lockup) range, current does not flow to proportional solenoid (1).
Pressure control valve (3) drains the oil from clutch port (A) through drain port (T), and sta- tor clutch is “released“. Also at this time, fill switch (5) is turned “off“ because oil pressure is not applied to pressure detection valve (4). D155AX-6 23