Komatsu D155AX-6 — REMOVAL AND INSTALLATION OF DAMPER ASSEMBLY

SEN01206-00 50 Disassembly and assembly Power train, Part 1 1 Removal and installation of damper assembly 1 Removal 1. Drain the oil in damper case. 6 Damper case: 1.5 l 2. Remove floor frame assembly referring to the section, "Removal and installation of floor frame assembly". 3. Remove work equipment and HSS pump assembly referring to the section, "Removal and installation of work equipment and HSS pump assembly". 9. Remove mounting bolts for damper cover assembly (5), and install two guide bolts [1] diagonally. [*2] 10. Using forcing bolt [2], pull out damper cover assembly (5) so that the lifting tool can be applied, and then remove it. [*3] 4.

Remove the cooling fan pump assembly refer- ring to the section, "Removal and installation of cooling fan pump assembly". 4 Damper cover assembly: 60 kg 5. Disconnect breather hose (1). 6. Remove oil level gauge (2). 7. Sling universal joint assembly (3) and remove it. [*1] 4 Universal joint assembly: 20 kg 8. Pull out torque converter side coupling (4). 2 D155AX-6