Komatsu D155AX-6 — 90 DIAGRAMS AND DRAWINGS

50 Disassembly and assembly SEN01206-00 Disconnection and connection of power train unit assembly 1 5. Remove tube (5). Disconnection 6. Remove work equipment and HSS pump assem- bly (6). 1. Set power train unit assembly (1) on block [1]. 4 Work equipment and HSS pump assem- bly: 110 kg 4 Power train unit assembly: 2,400 kg 7. Remove cooling fan pump assembly (7). 4 Cooling fan pump assembly: 25 kg 2. Disconnect all the connectors from power train unit to remove wiring harness referring to Dia- grams and drawings section, "Electrical circuit diagram, Connector table and arrangement drawing". 8. Remove tubes (8) and (9), and remove scavenging pump assembly (10). 3.

Remove cover (2), and remove pressure pickup hose (3). [*1] a Disconnect 10 pressure pickup hoses at power train unit side. 4 Scavenging pump assembly: 20 kg 4. Disconnect hose (4). D155AX-6 15