Komatsu D155AX-6 — HYDRAULIC, HSS PUMP

10 Structure, function and maintenance standard SEN00605-00 (2) When the main pump is under heavy load q If the emergency pump drive switch is turned on In the same way as in above, the command current (X) sent to PC-EPC valve solenoid (1) becomes constant. q The curve resulting when the emergency pump drive switch is ON is situated further to the left (B) than when the pump controller is normal (A). q For this reason, the force of piston (2) pushing spool (3) is constant. q If pump discharge pressure (PP) increases, spool (3) moves to the right from the position where the load of the pump is smaller, and bal- anced at the above diagram position.

q In this case, the pressure from port (B) flows to port (C), so servo piston (9) moves to the right (smaller pump delivery) and stops at a position to the further to the right then when the load on the pump is light. q The curb of pump discharge pressure (PP) and pump delivery (Q) is shown in the diagram. It is determined corresponding to the electric cur- rent value sent from the PC-EPC valve sole- noid through the resistor even when the emergency pump driving switch turns ON. D155AX-6 33