SEN00605-00 10 Structure, function and maintenance standard 2) When signal current is very small (coil is energized) 3) When signal current is maximum (coil is energized) q When a very small signal current flows to coil (2), coil (2) is energized, and a propulsion force is generated on the right side of plunger (7). q As the signal current flows to coil (2), coil (2) is energized. q Rod (6) pushes spool (5) to the right, and pres- surized oil flows from port (P) to port (C). q When this happens, the signal current is at its maximum, so the propulsion force of plunger (7) is also at its maximum.
q Pressures on port (C) increases and the force to act on spool (5) surface and the spring load on spring (4) become larger than the propul- sion force of plunger (7). q Spool (5) is pushed toward the right side by rod (6). q Hydraulic oil from port (P) flows to port (C) with maximum flow rate. As the result, the circuit pressure between the EPC and PC valves becomes maximum. q Spool (5) is pushed to the left, and port (P) is shut off from port (C). q Port (C) and port (T) are connected. q Since port (T) is closed, pressurized oil does not flow to the tank.
q Spool (5) moves up and down so that the pro- pulsion force of plunger (7) may be in balance with pressure of port (C) + spring load of spring (4). q Circuit pressure between the EPC valve and PC valve is controlled in proportion to the size of the signal current. 36 D155AX-6