SEN00607-00 10 Structure, function and maintenance standard Accumulator 1 Function q The accumulator is installed between the redusing valve and the EPC valve. Even if the engine is started with the work equipment still raised, the pressure of the nitrogen gas com- pressed inside the accumulator sends the pilot pressure to the control valve to actuate it and enable the work equipment to move down under its own weight. For EPC valve Operation q After the engine is stopped, when the EPC valve is at neutral, chamber (A) inside the blad- der is compressed by the oil pressure in cham- ber (B).
q When the EPC valve is operated, the oil pres- sure in chamber (B) goes below 2.9 MPa {30 kg/cm 2 }, and the pressure of the nitrogen gas in chamber (A) expands the bladder, so the oil in chamber (B) acts as the pilot pressure and actuates the main control valve. 1. Gas plug 2. Shell 3. Poppet 4. Holder 5. Bladder 6. Oil port Specifications Type of gas: Nitrogen Gas volume: 500 cc Max. actuation pressure: 6.86 MPa {70 kg/cm 2 } Min. actuation pressure: 0.69 MPa {7 kg/cm 2 } 10 D155AX-6