Komatsu D155AX-6 — PCCS LEVER

SEN00607-00 10 Structure, function and maintenance standard 2. Output voltage characteristics q The control unit is installed to the left control stand and the control lever is installed directly onto it. q The operating angle (stroke) of the control levers sensed with potentiometers and signal voltages are output to the transmission, steering controller. q A potentiometer is installed in each of longitudinal direction and lateral direction. Each potentiometer outputs 2 signal voltages which are opposite to each other as shown in the figure at right. 14 D155AX-6