10 Structure, function and maintenance standard SEN00607-00 Control of oil flow 1. Steering valve 1) At “hold“ Function q Chamber (G) is drained through chamber (H) to chamber (F). q Use of the CLSS circuit (Closed Center Load Sensing System) makes it possible to control the oil flow by adjusting the area of opening of the spool driven by the EPC valve regardless of the load. q Since the pump discharge pressure is acting on the left end of spool (3) of the steering prior- ity valve, it compresses spring (4) and moves to the right to the maximum stroke position. Operation q In this condition, the area of the opening to steering spool (1) is at its minimum.
q When the steering spool (1) is at the “hold“ position, the pump discharge pressure is sent from chamber (A) through the notch in spool (3) of the steering priority valve, and passes through chamber (B) to chamber (C). D155AX-6 31