10 Structure, function and maintenance standard SEN00607-00 Function q When the blade lift valve is at “float“, the cylin- der port and drain port are connected to put the circuit in a no-load condition. q When the blade lift valve is in the “float“ condi- tion, the pump passage and cylinder ports (A3) and (B3) are separated so that the other con- trol valves can be operated. Operation q When the work equipment control lever is at the “lower“ position and the “float“ button is pressed, output pressure (PA3) of the EPC valve becomes 3.4 MPa {35 kg/cm 2 or more and blade lift spool (1) is moved to the maxi- mum stroke position.
q Ports (A3) and (B3) and LS passage (O) are all connected to the drain circuit, so there is no load on the blade lift cylinder. q If the blade lift cylinder is driven by the weight of the blade, the oil entering from port (A3) flows to ports (A), (B), (B') and (A'), while the rest of the pressurized oil flows through ports (C) and (D), and is drained. q The oil flow is throttled by the area of opening between ports (A) and (B) of blade lift spool (1), and the cylinder speed is controlled. q The pump circuit chamber (E) and ports (A3) and (B3) are separated, and pump discharge pressure (P) is formed at chamber (E), so it is possible to carry out compound operations with other control valves.
D155AX-6 39