Komatsu D155AX-6 — CONTROL VALVE

10 Structure, function and maintenance standard SEN00607-00 P1 = P3 + P4 = Differential pressure between ports (M) and (E) P2 = Differential pressure between ports (E) and (N) P3 = Differential pressure between ports (M) and (B) P4 = Differential pressure between ports (B) and (E) LS = P1 + P2 = Differential pressure between ports (M) and (N) = 2.0 MPa {20 kg/cm 2 } Function q It sets the maximum pressure when HSS motor (7) is operated. q If steering spool (1) is moved and the pressure of HSS motor (7) becomes higher, the poppet of steering LS relief valve (5) will start to open and oil will be drained from LS circuit (O).

(Ports (E), (F), (G), (J), (K) and (L)) Operation q As a result, there will be a drop in pressure in LS passage (O) starting from LS sensing hole (F), and P2 will become larger. q For the same reason, if the pressure in cham- bers (H) and (I) drops, steering priority valve spool (2) will push against spring (3) and move to the right, and will make the opening between chambers (B) and (C) smaller, so the flow to chambers (B) and (C) will be throttled and P4 will become larger.

q Because of the pump swash plate control, the system circuit is balanced at a circuit pressure which makes the pressure loss generated by the flow at steering LS relief valve (5), P1 + P2, equal to LS differential pressure ( LS). q When this happens, the pump LS valve detects the differential pressure generated by steering LS relief valve (5), and moves the pump swash plate from the maximum to the minimum position. The pump swash plate is balanced at a position where the LS differential pressure is 2.0 MPa {20 kg/cm 2 }.

q When the pump is at the minimum swash plate angle (minimum oil flow), if the minimum oil flow is greater than the LS relief oil flow + leak- age at any part, the pressure is confined in the pump circuit (between the pump and chambers (A) and (B)), so the LS differential pressure rises. q If this differential pressure goes above the set pressure for unload valve (4), the unload valve is actuated to relieve the excess oil flow and balance the circuit. D155AX-6 41