Komatsu D155AX-6 — CONTROL VALVE

10 Structure, function and maintenance standard SEN00607-00 Function q This improves the response of the system including the pump swash plate and pressure compensation valve by sending the pilot pres- sure (basic pressure of EPC valve) to the LS circuit, and compensating the rise of the LS cir- cuit pressure. Operation q When blade lift valve spool (1) is at the “hold“ position, pilot pressure (P1) (basic pressure of EPC valve) is sent through preset check valve (3) to chamber (F) of the pressure compensa- tion valve. This pressure is called preset pres- sure (P2). q Unload pressure (P) is being sent to chamber (B), but (P1) + (F0) > (P) (F0:

load of spring (4)), so pressure compensation spool (2) moves to the left and the size of the opening between chambers (A) and (B) becomes the maximum. q When blade lift spool (1) is switched, unload pressure (P) flows immediately through cham- bers (A), (B), (C), (D) and (E) to the blade lift cylinder, so the pressure at the port starts to rise and the time lag becomes smaller. q At the same time, preset pressure (P2) is sup- plied to LS circuit (O), and the pressure in the LS circuit rises. q Unload valve (7) closes, and oil is sent further to the pump LS valve to improve the response of the pump swash plate angle.

This makes it possible to reduce the response time for giving the necessary oil flow. D155AX-6 51