10 Structure, function and maintenance standard SEN00607-00 Unit: mm No. Remedy 11 Replace spring if damaged or deformed. 12 Function q The self pressure reducing valves reduce the discharge pressure of the fan pump and sup- plies it to the PPC valve, the EPC valve, etc. as the control pressure.
D155AX-6 63 Check item Criteria Spring (pressure reducing valve main) Standard size Repair limit Free length In x outer diameter stallation length Installation load Free length Installation load 19.2 x 7.20 16.1 19.6 N {2.0 kg} — 17.7 N {1.80 kg} Spring (pressure reduction valve pilot) 17.8 x 7.20 12.7 28 N {2.90 kg} — 25.6 N {2.60 kg} Spring 71.0 x 18.0 59.0 200 N {20.4 kg} — 186 N {19.0 kg} Spring (safety valve) 16.1 x 7.80 13.4 61.7 N {6.30 kg} — 58.8 N {6.0 kg}