Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

30 Testing and adjusting SEN00681-01 a Remedies given by displayed action codes to operator to take (The following table is an excerpt from the Operation and Maintenance Manual) D155AX-6 13 Action code Method of indicating trouble Examples of trouble Remedy given to operator to take E01 • Action code and failure code are displayed. • Backup alarm does not sound. • Fan speed is kept at maximum. • Although all or a part of automatic function stops, machine can be operated. • Ask your Komatsu distributor for repair. E02 • Action code and failure code are displayed. • Alarm buzzer sounds. • Gear is not shifted up or down. • Engine boost pressure is abnor- mal.

• Exhaust gas color is bad when temperature is low. • If operator stops and restarts engine, machine can be operated without limiting any function. Operator must take care, how- ever. • Ask your Komatsu distributor for repair. E03 • Action code and failure code are displayed. • Telephone No. is displayed (if set). • Alarm buzzer sounds. • Engine coolant temperature sen- sor is abnormal. • Usable gear speeds are limited. • Engine speed does not rise to maximum. • Gearshift shock is increased. • Steering performance lowers. • Braking shock is increased. • Move machine to safe place. • Ask your Komatsu distributor for repair. E04 • Action code and failure code are displayed. • Telephone No.

is displayed (if set). • Alarm buzzer sounds. • Engine cannot be controlled. • Machine cannot travel. • Machine stops. • Stop machine immediately. • Ask your Komatsu distributor for repair.