Komatsu D155AX-6 — SPECIAL FUNCTIONS OF MACHINE MONITOR (EMMS)

30 Testing and adjusting SEN00681-01 D155AX-6 31 Action code Failure code Trouble (Displayed on screen) Alarm buzzer Component in charge Category of history E03 DFAAL8 RL lever: Signal mismatch q W/E Electrical system E03 DFABKA RL lever 1: Disconnection q W/E Electrical system E03 DFABKB RL lever 1: Short circuit q W/E Electrical system E03 DFACKA RL lever 2: Disconnection q W/E Electrical system E03 DFACKB RL lever 2: Short circuit q W/E Electrical system E03 DFADKX RT lever 1: Out of normal range q W/E Electrical system E03 DFADKZ RT lever: Disconnection or short circuit q W/E Electrical system E03 DFADL8 RT lever: Signal mismatch q W/E Electrical system E03 DFAEKA RT lever 1:

Disconnection q W/E Electrical system E03 DFAEKB RT lever 1: Short circuit q W/E Electrical system E03 DFAFKA RT lever 2: Disconnection q W/E Electrical system E03 DFAFKB RT lever 2: Short circuit q W/E Electrical system E01 DGT1KA T/C oil temp sensor: Abnormal P/T Electrical system E01 DGT1KX T/C oil temp sensor abnormal P/T Electrical system DH21KA WEQ pressure sensor: Disconnection W/E Electrical system DH21KB WEQ pressure sensor: Short circuit W/E Electrical system E02 DHT5KA T/C in-pressure sensor: Disconnection q P/T Electrical system E02 DHT5KB T/C in-pressure sensor: Short circuit q P/T Electrical system E02 DHT7KA T/C out-pressure sensor:

Disconnection q P/T Electrical system E02 DHT7KB T/C out-pressure sensor: Short circuit q P/T Electrical system E03 DK10KX Fuel control Dial: Out of normal range q P/T Electrical system E03 DK30KA ST lever 1: Disconnection q P/T Electrical system E03 DK30KB ST lever 1: Short circuit q P/T Electrical system E04 DK30KX ST lever 1: Out of normal range q P/T Electrical system E04 DK30KZ ST lever: Disconnection or short circuit q P/T Electrical system E03 DK30L8 ST lever: Signal mismatch q P/T Electrical system E03 DK31KA ST lever 2: Disconnection q P/T Electrical system E03 DK31KB ST lever 2: Short circuit q P/T Electrical system E03 DK40KA Brake potentiometer:

Disconnection q P/T Electrical system E03 DK40KB Brake potentiometer: Short circuit q P/T Electrical system E04 DK55KX FR lever: Out of normal range q P/T Electrical system E04 DK55KZ FR lever: Disconnection or short circuit q P/T Electrical system E03 DK55L8 FR lever: Signal mismatch q P/T Electrical system E03 DK56KA FR lever 1: Disconnection q P/T Electrical system E03 DK56KB FR lever 1: Short circuit q P/T Electrical system E03 DK57KA FR lever 2: Disconnection q P/T Electrical system E03 DK57KB FR lever 2: Short circuit q P/T Electrical system