SEN00681-01 30 Testing and adjusting Default setting (Key-on Mode) Check or change various settings related to the machine monitor and machine by default setting. The function of Key-on Mode is used to set the ini- tial mode displayed on the machine monitor when the starting switch is turned ON. 3. Selecting mode After the "Key-on Mode" screen is displayed, select the mode to be set with the function switches. q Mode at previous key-OFF: Final mode in previous operation is displayed when starting switch is turned ON 1. Selecting menu Select "06 Default" on the "Service Menu" screen. q Default Value (ALL OFF): Default setting of all mode items (Power: E, other 3 items:
OFF) is displayed when starting switch is turned ON q [F3]: Move to lower item q [F4]: Move to upper item q [F5]: Cancel selection and return to default screen q [F6]: Confirm selection and return to default screen a When the machine is delivered, Default Value (All OFF). 2. Selecting sub menu After the "Default" screen is displayed, select "01 Key-on Mode" with the function switches or numeral input switches. a Select this item similarly to an item on the "Service Menu" screen. a This function sets the following 4 mode items (which are the items set with the customize switch in the operator mode). q Power: P/E q Reverse slow mode: ON/OFF q Work equipment fine control:
ON/OFF q Blade slow down: ON/OFF 40 D155AX-6