Komatsu D155AX-6 — 40 TROUBLESHOOTING

30 Testing and adjusting SEN00682-01 Pm Clinic undercarriage check sheet 1. Bushing temperature Left side of machine a Symbols to be entered in check drawing H : Hot (You cannot keep touching, Very hot, Min. 50 °C) W : Warm (Lukewarm, warmer than link, Approx. 35 °C) C : Normal temperature: Same as link temperature Right side of machine a Symbols to be entered in check drawing H : Hot (You cannot keep touching, Very hot, Min. 50 °C) W : Warm (Lukewarm, warmer than link, Approx. 35 °C) C : Normal temperature: Same as link temperature D155AX-6 13 Machine mode l Serial No.

Service meter User's name Date of execution Inspector D155AX-6 Item Measurement condition Measurement result Accepted Re jected Under- carriage Bushing temperature Measure just after work. Left side of machine Right side of machine