Komatsu D155AX-6 — FAILURE CODE [15SJLH] L/U: FILL LOW

SEN00716-01 40 Troubleshooting Failure code [15SJLH] L/U: Fill low 1 30 D155AX-6 Action code Failure code Trouble L/U: Fill low (Power train controller system) E02 15SJLH Contents of trouble • When output to torque converter lockup clutch ECMV solenoid circuit is turned ON, fill switch signal is turned OFF. Action of controller • None in particular. Problem that appears on machine • Engine may stall during travel. Related information • State of lockup clutch ECMV fill switch signal can be checked with monitoring function. (Code: 31520 T/M Fill Sw Input 2) • Method of reproducing failure code: Start engine + Set transmission in forward position (in auto- matic gearshift mode).

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective lockup clutch ECMV fill switch (Internal dis- connection) a Prepare with starting switch OFF, then start engine, select automatic gearshift mode, and carry out troubleshooting. FLUC (male) PCCS lever (Travel gear speed) Resistance Between (1) – chas- sis ground N Min. 1 Mz Locked up at F1, F2, or F3 Max. 1 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between STC2 (female) (36) – FLUC (female) (1) Resis- tance Max. 1 z 3 Defective power train con- troller a Prepare with starting switch OFF, then start engine, select automatic gearshift mode, and carry out troubleshooting. STC2 PCCS lever (Travel gear speed) Voltage Between (36) – chas- sis ground N 5 – 11 V Locked up at F1, F2, or F3 Max. 1 V 4 Defective hydraulic system If causes 1 – 3 are not detected in electrical system, hydraulic sys- tem may be defective. Carry out related troubleshooting (H mode).