Komatsu D155AX-6 — FAILURE CODE [2301L1] RIGHT BRAKE: FILL HIGH

SEN00716-01 40 Troubleshooting Failure code [2301L1] Right brake: Fill high 1 Circuit diagram related to steering case right brake ECMV 32 D155AX-6 Action cod e Failure code Trouble Right brake: Fill high (Power train controller system) E04 2301L1 Contents trouble of • When output to steering case right brake ECMV solenoid circuit is turned OFF, fill switch signal is turned ON. Action of controller • Limits operation of engine, transmission, and brake. Problem th appears o machine at • Applies brake lightly during travel. n • Once machine is stopped, engine speed is limited to medium (half). • Once machine is stopped, machine cannot travel at all.

Related informatio • State of right brake ECMV fill switch signal can be checked with monitoring function. (Code: 31521 S/T Fill Sw Input) n • Method of reproducing failure code: Start engine + Operate parking brake lever (Free) + Operate brake pedal (Press).

Possible cau and standa value in nor state Cause Defective right brake ECMV 1 fill switch (Internal short cir- cuit) ses Ground fault in wiring har- rd 2 ness (Contact with GND cir- mal cuit) Defective power train con- 3 troller 4 Defective hydraulic system Standard value in normal state/Remarks on troubleshooting Defective right brake ECMV fill switch (Internal short cir- cuit) a Prepare with starting switch OFF, then start engine, set parking brake lever in Free position, and carry out troubleshooting. FBRR (male) Brake pedal Resistance Between (1) – chas- sis ground Released Max. 1 z Pressed Min.

1 Mz Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC2 (female) (38 – FBRR (female) (1) and chassis ground ) Resis- Min tance . 1 Mz Defective power train con- troller a Prepare with starting switch OFF, then start engine, set parking brake lever in Free position, and carry out troubleshooting. STC2 Brake pedal Voltage Between (38) – chas- sis ground Released Max. 1 V Pressed 5 – 11V Defective hydraulic system If causes 1 – 3 are not detected in electrical system, hydraulic sys- tem may be defective. Carry out related troubleshooting (H mode).