Komatsu D155AX-6 — FAILURE CODE [7RFRKA] ECM HOLD RELAY: DISCONNECTION

SEN00716-01 40 Troubleshooting Failure code [7RFAKA] ECM HOLD RELAY: Disconnection 1 36 D155AX-6 Action code Failure code Trouble ECM HOLD RELAY: Disconnection (Power train controller system) — 7RFAKA Contents of trouble • When ground circuit of engine cut relay circuit is disconnected to turn output ON, no current flows. Action of controller • None in particular. Problem that appears on machine • When engine cut mechanism is installed, engine cannot be cut (stopped). Related information • State of engine cut relay circuit signal can be checked with monitoring function. (Code: 40912 P/T Sw Input) • Method of reproducing failure code: Start engine.

• This failure code detects abnormality on primary side (coil side) of engine cut relay but does not detect abnormality on secondary side (contact side). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective engine cut relay (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. ACT (male) Resistance Between (1) – (2) 200 – 400 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between STC2 (female) (19) – ACT (female) (2) Resis- tance Max. 1 z Wiring harness between ACT (female) (1) – terminal 270. Resis- tance Max. 1 z 3 Short circuit in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC2 (female) (19) – ACT (female) (2) and chassis ground Resis- tance Min. 1 Mz Wiring harness between ACT (female) (1), (3) – terminal 270, circuit branch end and chassis ground. Resis- tance Min. 1 Mz 4 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

STC2 Voltage Between (19) – chassis ground 20 – 30 V