Komatsu D155AX-6 — FAILURE CODE [AA10NX] AIR CLEANER CLOGGING

SEN00716-01 40 Troubleshooting Failure code [AA10NX] Air Cleaner Clogging 1 *1: Max. -3,430 Pa {-350 mmH 2 O} *2: -7,470 ± 490Pa {-762 ± 50 mmH 2 O} 38 D155AX-6 Action code Failure code Trouble Air Cleaner Clogging (Machine monitor system) — AA10NX Contents of trouble • While engine was running, air cleaner clogging switch signal circuit detected clogging of air cleaner (opening of sensor contact). Action of machine monitor • None in particular. Problem that appears on machine • If machine is used as it is, engine may be damaged. Related information • Method of reproducing failure code: Start engine.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Clogged air cleaner (When system is normal) a Air cleaner may be clogged. Check and clean or replace it. 2 Defective air cleaner clog- ging switch (Internal discon- nection) a Prepare with starting switch OFF, then start engine and carry out troubleshooting. AF1 (male) Air cleaner Resistance Between (1) – (2) Normal (Intake air resistance: *1) Max. 1 z Clogged (Intake air resistance: *2) Min.

1 Mz 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CM02 (female) (4) – AF1 (female) (1) Resis- tance Max. 1 z Wiring harness between CM01 (female) (7), CM02 (female) (7) – AF1 (female) (2) Resis- tance Max. 1 z 4 Defective power train con- troller a Prepare with starting switch OFF, then start engine and carry out troubleshooting. CM02 Air cleaner Voltage Between (4) – (7) Normal (Intake air resistance: *1) Max. 1 V Clogged (Intake air resistance: *2) 20 – 30 V