Komatsu D155AX-6 — FAILURE CODE [AB00MA] BATTERY CHARGE ABNORMAL

SEN00716-01 40 Troubleshooting Failure code [AB00MA] Battery Charge Abnormal 1 40 D155AX-6 Action code Failure code Trouble Battery Charge Abnormal (Machine monitor system) — AB00MA Contents of trouble • While engine was running, alternator signal circuit detected that battery charge voltage was low. Action of machine monitor • Displays charge level monitor red on machine monitor. Problem that appears on machine • If machine is used as it is, battery may not be charged. Related information • Battery voltage can be checked with monitoring function. (Code: 03203 Battery Power Supply) • Method of reproducing failure code: Start engine.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective charge by alterna- tor (When system is normal) a Prepare with starting switch OFF, then start engine and carry out troubleshooting. CM01 Engine Voltage Between (11) – chas- sis ground Above medium speed 27.5 – 29.5 V 2 Defective charge level moni- tor system If cause 1 is not detected, charge level monitor system may be defective. Carry out "E-5 Caution item lights up while engine is running" in E mode.