SEN00717-01 40 Troubleshooting Troubleshooting by failure and error codes, Part 2 1 Failure code [CA111] EMC Critical Internal Failure 1 4 D155AX-6 Action code Failure code Trouble EMC Critical Internal Failure (Engine controller system) E04 CA111 Contents of trouble • Trouble occurred in engine controller. Action of controller • None in particular. Problem that appears on machine • Engine runs normally but may stop during operation or may not be able to start. Related information • Source voltage of engine controller can be checked with monitoring function. (Code:
03203 Battery Power Supply) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective circuit breaker (CB30 or CB8) If circuit breaker is turned OFF, circuit probably has ground fault. (See cause 3.) 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC3 (female) (3), (4) – CB8 (2) Resis- tance Max. 1 z Wiring harness between CB8 (1) – CB30 (B30S) Resis- tance Max. 1 z Wiring harness between CB30 (B30L) – ter- minal BRB Resis- tance Max.
1 z Wiring harness between EGC3 (female) (1), (2) – chassis ground (GND20) Resis- tance Max. 1 z 3 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC3 (female) (3), (4) – CB8 (2) and chassis ground Resis- tance Min. 1 Mz Wiring harness between CB8 (1) – CB30 (B30S), circuit branch end and chassis ground Resis- tance Min. 1 Mz Wiring harness between CB30 (B30L) – ter- minal BRB and chassis ground Resis- tance Min. 1 Mz Wiring harness between EGC3 (female) (1), (2) – chassis ground (GND20) and chassis ground Resis- tance Min.
1 Mz 4 Defective engine controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. EGC3 Starting switch Voltage Between (3), (4) – (1), (2) ON 20 – 30 V