SEN00717-01 40 Troubleshooting Failure code [CA227] Sens Supply 2 Volt High Error 1 32 D155AX-6 Action code Failure code Trouble Sens Supply 2 Volt High Error (Engine controller system) E03 CA227 Contents of trouble • Signal voltage in sensor power supply 2 (5 V) circuit is abnormally high. Action of controller • Operates Bkup speed sensor with signals of Ne speed sensor. • Sets oil pressure sensor to default value (250 kPa [2.55 kg/cm2}) and continues operation. • Sets ambient pressure to default value (52.44 kPa {0.53 kg/cm2}) and continues operation. • Fixes charge pressure sensor value (400 kPa [4.08 kg/cm2}) and continues operation.
• Sets EGR inlet pressure sensor to default value (102 kPa {1.05 kg/cm2}) and continues operation. • Limits output of EGR valve lift sensor and closes EGR valve and bypass valve. • Limits output of bypass valve lift sensor and closes EGR valve and bypass valve. Problem that appears on machine • Engine output drops. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective related system If another failure code is indicated, carry out troubleshooting for it. 2 Defective sensor (Internal trouble) a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
Disconnect devices at right in order. If "E" of failure code disappears when a device is discon- nected, that device has trouble in it. Bkup speed sensor G connector Oil pressure sensor POIL connector Ambient pressure sensor PAMB connector Charge pressure sensor PIM connector EGR inlet pressure sensor PEVA connector EGR valve lift sensor SEGR connector Bypass valve lift sensor SBP connector 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (37) – each sensor (female) Resis- tance Max.
1 z Wiring harness between EGC1 (female) (47) – each sensor (female) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (37) – each sensor (female) and chassis ground Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (47) – each sensor (female) and chassis ground Resis- tance Min. 1 Mz 5 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
Wiring harness between EGC1 (female) (37) – each sensor (female) and between EGC1 (female) (47) – each sensor (female) Resis- tance Min. 1 Mz 6 Defective engine controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. EGC1 Voltage Between (37) – (47) 4.75 – 5.25 V