SEN00717-01 40 Troubleshooting Failure code [CA451] Rail Press Sensor High Error 1 60 D155AX-6 Action code Failure code Trouble Rail Press Sensor High Error (Engine controller system) E03 CA451 Contents of trouble • Signal voltage in common rail pressure sensor circuit is abnormally high. Action of controller • Limits engine output and continues operation (Limits common rail pressure). Problem that appears on machine • Engine output drops. Related information • State of common rail pressure sensor signal can be checked with monitoring function. (Code:
36401 Rail Pressure Sens Volt) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor power sup- ply system If code [CA352] or [CA386] is indicated, carry out troubleshooting for it first. 2 Defective common rail pres- sure sensor (Internal trouble) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting. PFUEL Voltage Between (1) – (3) Power supply 4.75 – 5.25 V Between (2) – (3) Signal 0.26 – 4.6 V Sensor voltage is measured with wiring harness connected.
Accordingly, if voltage is abnormal, check wiring harness and con- troller, too, for another cause of trouble, and then judge. 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (33) – PFUEL (female) (1) Resis- tance Max. 1 z Wiring harness between EGC1 (female) (25) – PFUEL (female) (2) Resis- tance Max. 1 z Wiring harness between EGC1 (female) (47) – PFUEL (female) (3) Resis- tance Max.
1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (33) – PFUEL (female) (1) and chassis ground Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (25) – PFUEL (female) (2) and chassis ground Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (47) – PFUEL (female) (3) and chassis ground Resis- tance Min. 1 Mz 5 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
Wiring harness between EGC1 (female) (33) – PFUEL (female) (1) and between EGC1 (female) (25) – PFUEL (female) (2) Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (33) – PFUEL (female) (1) and between EGC1 (female) (47) – PFUEL (female) (3) Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (25) – PFUEL (female) (2) and between EGC1 (female) (47) – PFUEL (female) (3) Resis- tance Min. 1 Mz