Komatsu D155AX-6 — FAILURE CODE [CA1631] BP VALVE POS SENS HIGH ERROR

SEN00718-01 40 Troubleshooting Failure code [CA1631] BP Valve Pos Sens High Error 1 14 D155AX-6 Action code Failure code Trouble BP Valve Pos Sens High Error (Engine controller system) E03 CA1631 Contents of trouble • Signal voltage in bypass valve lift sensor circuit is abnormally high. Action of controller • Limits engine output and continues operation. • Closes EGR valve and bypass valve. Problem that appears on machine • Engine output drops. Related information • State of bypass valve lift sensor signal can be checked with monitoring function. (Code:

18201 BPS Valve Pos Sens Volt) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor power sup- ply system If code [CA187] or [CA227] is indicated, carry out troubleshooting for it first. 2 Defective bypass valve lift sensor (Internal trouble) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting. SBP Voltage Between (1) – (2) Power supply 4.75 – 5.25 V Sensor voltage is measured with wiring harness connected. Accordingly, if voltage is abnormal, check wiring harness and con- troller, too, for another cause of trouble, and then judge.

3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (37) – SBP (female) (1) Resis- tance Max. 1 z Wiring harness between EGC1 (female) (38) – SBP (female) (2) Resis- tance Max. 1 z Wiring harness between EGC1 (female) (29) – SBP (female) (3), (4) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between EGC1 (female) (37) – SBP (female) (1) and chassis ground Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (38) – SBP (female) (2) and chassis ground Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (29) – SBP (female) (3), (4) and chassis ground Resis- tance Min. 1 Mz 5 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (37) – SBP (female) (1) and between EGC1 (female) (38) – SBP (female) (2) Resis- tance Min.

1 Mz Wiring harness between EGC1 (female) (37) – SBP (female) (1) and between EGC1 (female) (29) – SBP (female) (3), (4) Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (38) – SBP (female) (2) and between EGC1 (female) (29) – SBP (female) (3), (4) Resis- tance Min. 1 Mz