Komatsu D155AX-6 — FAILURE CODE [CA1633] KOMNET DATALINK TIMEOUT ERROR

SEN00718-01 40 Troubleshooting Failure code [CA1633] KOMNET Datalink Timeout Error 1 18 D155AX-6 Action code Failure code Trouble KOMNET Datalink Timeout Error (Engine controller system) E03 CA1633 Contents of trouble • Trouble occurred in KOMNET (CAN) communication circuit between engine controller and machine monitor, power train controller, and work equipment controller. Action of controller • Operates in default mode or maintains condition when abnormality occurs.

Problem that appears on machine Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CM02 (female) (8), (9) – EGC2 (female) (46), STC2 (female) (32) or WEC2 (female) (32) Resis- tance Max. 1 z Wiring harness between CM02 (female) (10) – EGC2 (female) (47), STC2 (female) (22) or WEC2 (female) (22) Resis- tance Max.

1 z 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between CM02 (female) (8), (9) – EGC2 (female) (46), STC2 (female) (32), WEC2 (female) (32), ACCN (female) (17), SRV (male) (3) or CA1 (female) (A) and chassis ground Resis- tance Min. 1 Mz Wiring harness between CM02 (female) (10) – EGC2 (female) (47), STC2 (female) (22), WEC2 (female) (22), ACCN (female) (18), SRV (male) (10) or CA1 (female) (B) and chassis ground Resis- tance Min.

1 Mz 3 Hot short (Contact with GND circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between CM02 (female) (8), (9) – EGC2 (female) (46), STC2 (female) (32), WEC2 (female) (32), ACCN (female) (17), SRV (male) (3) or CA1 (female) (A) and chassis ground Voltage Max. 1 V Wiring harness between CM02 (female) (10) – EGC2 (female) (47), STC2 (female) (22), WEC2 (female) (22), ACCN (female) (18), SRV (male) (10) or CA1 (female) (B) and chassis ground Voltage Max.

1 V 4 Defective CAN terminal resistance (Internal discon- nection or short circuit) Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. CA1 (male) Resistance Between (A) – (B) Approx. 120 z 5 Defective engine controller If causes 1 – 4 are not detected, engine controller may be defec- tive. (Since trouble is in system, troubleshooting cannot be carried out.)