Komatsu D155AX-6 — FAILURE CODE [CA1653] EGR INLET PRESS SENS HIGH ERROR

SEN00718-01 40 Troubleshooting Failure code [CA1653] EGR Inlet Press Sens High Error 1 22 D155AX-6 Action code Failure code Trouble EGR Inlet Press Sens High Error (Engine controller system) E01 CA1653 Contents of trouble • Signal voltage in EGR inlet pressure sensor circuit is abnormally high. Action of controller • Sets EGR inlet pressure to default value (102 kPa {1.04 kg/cm2}) and continues operation. • Limits engine output and continues operation. Problem that appears on machine • Engine output drops. Related information • State of EGR valve inlet pressure sensor signal can be checked with monitoring function. (Code:

18001 EGR In Press Sens Volt) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor power sup- ply system If code [CA187] or [CA227] is indicated, carry out troubleshooting for it first. 2 Defective EGR inlet pressure sensor (Internal trouble) a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting. PEVA Voltage Between (1) – (2) Power supply 4.75 – 5.25 V Sensor voltage is measured with wiring harness connected. Accordingly, if voltage is abnormal, check wiring harness and con- troller, too, for another cause of trouble, and then judge.

3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (37) – PEVA (female) (1) Resis- tance Max. 1 z Wiring harness between EGC1 (female) (47) – PEVA (female) (2) Resis- tance Max. 1 z Wiring harness between EGC1 (female) (20) – PEVA (female) (3) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between EGC1 (female) (37) – PEVA (female) (1) and chassis ground Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (47) – PEVA (female) (2) and chassis ground Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (20) – PEVA (female) (3) and chassis ground Resis- tance Min. 1 Mz 5 Short circuit in wiring har- ness (with another wiring harness) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC1 (female) (37) – PEVA (female) (1) and between EGC1 (female) (47) – PEVA (female) (2) Resis- tance Min.

1 Mz Wiring harness between EGC1 (female) (37) – PEVA (female) (1) and between EGC1 (female) (20) – PEVA (female) (3) Resis- tance Min. 1 Mz Wiring harness between EGC1 (female) (47) – PEVA (female) (2) and between EGC1 (female) (20) – PEVA (female) (3) Resis- tance Min. 1 Mz 6 Defective engine controller a Prepare with starting switch OFF, then turn starting switch ON or start engine and carry out troubleshooting. EGC1 Voltage Between (37) – (47) 4.75 – 5.25 V