Komatsu D155AX-6 — FAILURE CODE [CA2556] GRID HTR RELAY VOLT HIGH ERROR

SEN00718-01 40 Troubleshooting Failure code [CA2556] Grid Htr Relay Volt High Error 1 36 D155AX-6 Action code Failure code Trouble Grid Htr Relay Volt High Error (Engine controller system) E01 CA2556 Contents of trouble • There is short circuit in intake air heater relay. Action of controller • None in particular. Problem that appears on machine • Engine does not start easily at low temperature. Related information • Engine controller has automatic preheating function, which is turned ON when engine coolant tem- perature is below -5 °C (for up to 30 seconds). • Engine coolant temperature can be checked with monitoring function. (Code:

04107 Coolant Temperature) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective intake air heater relay (Internal trouble) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. PHR (male) Resistance Between (1) – (2) 200 – 400 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC2 (female) (40) – PHR (female) (1) Resis- tance Max.

1 z Wiring harness between PHR (female) (2) – chassis ground (GND03) Resis- tance Max. 1 z 3 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between EGC2 (female) (40) – PHR (female) (1) and chassis ground Resis- tance Min. 1 Mz 4 Defective engine controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. EGC2 Coolant temperature Voltage Between (40) – chas- sis ground -5 °C or higher Max. 1 V Below -5 °C 20 – 30 V