Komatsu D155AX-6 — FAILURE CODE [D110KA] BATTERY RELAY: DISCONNECTION

SEN00718-01 40 Troubleshooting Failure code [D110KA] Battery relay: Disconnection 1 38 D155AX-6 Action code Failure code Trouble Battery relay: Disconnection (Power train controller system) – D110KA Contents of trouble • Turns signal to battery relay holding circuit, no current flows. Action of controller • Turns signal to battery relay holding circuit OFF. Problem that appears on machine • Problem may occur in writing data into ROM (non-volatile memory) of each controller. Related information • tate of battery relay holding circuit signal can be checked with monitoring function. (Code: 60600 BR Hold Relay) • Method of reproducing failure code: Turn starting switch ON o OFF.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective battery relay (Inter- nal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Battery relay Continuity Between terminals SW – BRE There is continuity 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC3 (female) (4) – terminal SW Resis- tance Max. 1 z Wiring harness between terminal BRE and chassis ground Resis- tance Max.

1 z 3 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between STC3 (female) (4) – terminal SW, terminal 260, terminal AL/R or circuit branch end and chassis ground Voltage Max. 1 V 4 Defective power train con- troller a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. STC3 Starting switch Voltage Between (4) – chas- sis ground OFF Max. 1 V