Komatsu D155AX-6 — FAILURE CODE [D110KB] BATTERY RELAY: DRIVE SHORT CIRCUIT

SEN00718-01 40 Troubleshooting Failure code [D110KB] Battery Relay: Drive Short Circuit 1 40 D155AX-6 Action code Failure code Trouble Battery Relay: Drive Short Circuit (Power train controller system) – D110KB Contents of trouble • When signal was output to battery relay circuit, abnormal current flowed. Action of controller • Turns signal to battery relay holding circuit OFF. Problem that appears on machine • Problem may occur in writing data into ROM (non-volatile memory) of each controller. Related information • State of battery relay holding circuit signal can be checked with monitoring function. (Code: 60600 BR Hold Relay) • Method of reproducing failure code:

Turn starting switch ON o OFF. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective battery relay (Inter- nal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Battery relay Continuity/Resistance Between terminals SW – BRE There is continuity Between terminal SW – chassis ground Min. 1 Mz 2 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

Wiring harness between STC3 (female) (4) – terminal SW, terminal 260 or RSD (female) (1) and chassis ground Resis- tance Min. 1 Mz 3 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC3 Starting switch Voltage Between (4) – chas- sis ground ON 20 – 30 V