Komatsu D155AX-6 — FAILURE CODE [D130KA] NEUTRAL RELAY: DISCONNECTION

SEN00718-01 40 Troubleshooting Failure code [D130KA] Neutral relay: Disconnection 1 42 D155AX-6 Action code Failure code Trouble Neutral relay: Disconnection (Power train controller system) E02 D130KA Contents of trouble • When ground circuit of neutral safety relay circuit is disconnected, no current flows. Action of controller • Turns output of neutral safety relay circuit OFF. Problem that appears on machine • Engine cannot be started. Related information • State of neutral safety relay circuit signal can be checked with monitoring function. (Code: 59099 T/M Lock Relay) • Method of reproducing failure code: Turn starting switch ON + Operate parking brake lever (Free).

• This failure code detects abnormality on primary side (coil side) of neutral safety relay but does not detect abnormality on secondary side (contact side). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse (FS2-5) If fuse is broken, circuit probably has ground fault (See cause 4). 2 Defective neutral safety relay (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.

NSF (male) Resistance Between (1) – (2) 300 – 600 z 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC2 (female) (8) – NSF (female) (2) Resis- tance Max. 1 z Wiring harness between NSF (female) (1) – FS21 (5) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC2 (female) (8) – NSF (female) (2) and chassis ground Resis- tance Min.

1 Mz Wiring harness between NSF (female) (1) – FS21 (5) or circuit branch end and chassis ground Resis- tance Min. 1 Mz 5 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC2 Parking brake lever Voltage Between (8) – chas- sis ground Lock Max. 1 V Free 20 – 30 V