SEN00718-01 40 Troubleshooting Failure code [D130KB] Neutral relay: Short circuit 1 44 D155AX-6 Action code Failure code Trouble Neutral relay: Short circuit (Power train controller system) E02 D130KB Contents of trouble • When ground circuit of neutral safety relay was disconnected, abnormal current flowed. Action of controller • Turns output of neutral safety relay circuit OFF. Problem that appears on machine • Engine cannot be started. Related information • State of neutral safety relay circuit signal can be checked with monitoring function. (Code: 59099 T/M Lock Relay) • Method of reproducing failure code: Turn starting switch ON + Operate parking brake lever (Free).
• This failure code detects abnormality on primary side (coil side) of neutral safety relay but does not detect abnormality on secondary side (contact side). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective neutral safety relay (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. NSF (male) Resistance Between (1) – (2) 300 – 600 z 2 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
Wiring harness between STC2 (female) (8) – NSF (female) (2) and chassis ground Voltage Max. 1 V 3 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC2 Parking brake lever Voltage Between (8) – chas- sis ground Lock Max. 1 V Free 20 – 30 V