SEN00718-01 40 Troubleshooting Failure code [D161KA] Back-up alarm relay: Disconnection 1 46 D155AX-6 Action code Failure code Trouble Back-up alarm relay: Disconnection (Power train controller system) E01 D161KA Contents of trouble • When ground circuit of back-up alarm relay circuit is disconnected, no current flows. Action of controller • Turns output of back-up alarm relay circuit OFF. Problem that appears on machine • Back-up alarm does not sound Related information • State of back-up alarm relay circuit signal can be checked with monitoring function. (Code: 70400 Back Alarm Relay) • Method of reproducing failure code: Turn starting switch ON + Operate PCCS lever (R: Reverse).
• This failure code detects abnormality on primary side (coil side) of back-up alarm relay but does not detect abnormality on secondary side (contact side). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse (FS1-2) If fuse is broken, circuit probably has ground fault (See cause 4). 2 Defective back-up alarm relay (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON.
BKA (male) Resistance Between (1) – (2) 300 – 600 z 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC2 (female) (18) – BKA (female) (2) Resis- tance Max. 1 z Wiring harness between BKA (female) (1) – FS12 (2) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. Wiring harness between STC2 (female) (18) – BKA (female) (2) or circuit branch end and chassis ground Resis- tance Min.
1 Mz Wiring harness between BKA (female) (1), (3) – FS12 (2) and chassis ground Resis- tance Min. 1 Mz 5 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC2 PCCS lever (Directional) Voltage Between (18) – chas- sis ground N 20 – 30 V R (Reverse) Max. 1 V