Komatsu D155AX-6 — FAILURE CODE [D161KB] BACK-UP ALARM RELAY: SHORT CIRCUIT

SEN00718-01 40 Troubleshooting Failure code [D161KB] Back-up alarm relay: Short circuit 1 48 D155AX-6 Action code Failure code Trouble Back-up alarm relay: Short circuit (Power train controller system) E01 D161KB Contents of trouble • When ground circuit of back-up alarm relay was disconnected, abnormal current flowed. Action of controller • Turns output of back-up alarm relay circuit OFF. Problem that appears on machine • Back-up alarm does not sound. Related information • State of back-up alarm relay circuit signal can be checked with monitoring function. (Code: 70400 Back Alarm Relay) • Method of reproducing failure code: Turn starting switch ON + Operate PCCS lever (R:

Reverse) • This failure code detects abnormality on primary side (coil side) of back-up alarm relay but does not detect abnormality on secondary side (contact side). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective back-up alarm relay (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshoot- ing without turning starting switch ON. BKA (male) Resistance Between (1) – (2) 300 – 600 z 2 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.

Wiring harness between STC2 (female) (18) – BKA (female) (2) or circuit branch end and chassis ground Voltage Max. 1 V 3 Defective power train con- troller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. STC2 PCCS lever (Directional) Voltage Between (18) – chas- sis ground N 20 – 30 V R (Reverse) Max. 1 V